Author Topic: GESTETNER copier Error Code SC366 sc 367 sc 364 sc 365 problem solution (Read 795 times) HenryS Administrator Sr. Member ***** Posts: 346 Karma: +0/-0 zoomm View Profile CopierLiquidationCenter GESTETNER copier Error Code SC366 sc 367 sc 364 sc 365 problem solution « on: July 17, 2012, 09:42:02 AM » GESTETNER copier Error code SC366 error code SC367 SC364 SC365 problem GESTETNER copier: Error code SC366 is TD sensor (Vt low) error ( C- cyan ) GESTETNER : Error code SC367 is TD sensor (Vt low) error ( Y-yellow ) GESTETNER: Error code SC364 is TD sensor (Vt low) error ( K- black ) GESTETNER : Error code SC365 is TD sensor (Vt low) error ( M- magenta ) The Vt value of the cyan, magenta, black or yellow TD sensor is below the specified value with SP3020-004 (default is 0.5V) for 10 counts. - TD sensor wires disconnected, defective or loose. - A drawer connector disconnected, defective or loose. - TD sensor is defective SOLUTIONS: 1. Check the cyan, or yellow TD sensor connectors and wores between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.