If Id been thinking, Id have snapped a pic of the metering board in the ECO-6. Got a Directional Coupler that had been tested in an ECO-10 and worked fine. When installed on the ECO-6, the Inc & Ref meters both went negative. Turns out the ECOs can accepted + or - DC voltage. The terminal strip on the metering board has a + and a - input. Moving the appropriate wire (from memory, I had to move from 7 to 6 and from 10 to 9) got the polarity correct. Apparently different ECOs were set up for different diodes. Living proof that as Chris Hall stated earlier today, no two Energy Onix boxes are exactly the same. Bernie keeps us guessing, even after hes gone.